DEUTSCH Jiffy Splices are a unique, field-serviceable alternative to permanent splices. Made from the same high-quality silicone elastomer as DEUTSCH connector seals and grommets, the Jiffy Splice body houses a contact retention system that secures a mated pair of contacts in a compact environmentally sealed unit. Jiffy Splices are easy to install and service.

Contact Insertion

Step 1:

Grasp contact approximately one inch behind the contact crimp barrel.

Step 2:

Hold Jiffy Splice between thumb and forefinger approximately one-half inch behind cavity.

Step 3:

Push contact into Jiffy Splice until a positive stop is felt. An audible “snap” will occur when correctly mated. A light tug will confirm it is properly seated.

Contact Removal

Step 1:

Snap appropriate size removal tool over the wire.

Step 2:

Hold Jiffy Splice between thumb and forefinger about one-half inch behind cavity. Slide tool into cavity until resistance is felt and retaining fingers are engaged. Don't twist or insert tool at an angle.

Step 3:

Grip Jiffy Splice between thumb and forefinger and slowly pull contact wire assembly with removal tool out of cavity.

Retention fingers snap behind shoulder of contacts locking them in place. An audible click will signal a proper insertion. (cut away view)